    Background

    The impact of procedure location on clinical outcomes after TAVR remains unclear. We aimed to compare short-term outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) in the catheterization laboratory (CATH) versus surgical operating room (OR).

    Methods

    A retrospective review of 63,581 trans-femoral TAVR patients using balloon-expandable valves from 2015 to 2018 were captured utilizing the TVT Registry. Propensity score matching was performed using 24 covariates resulting in 2 risk-adjusted groups. Patients were further stratified by STS Risk Score with outcomes compared.

    Results

    Propensity score matching resulted in 24,160 risk-matched CATH and OR patient pairs. Short-term clinical outcomes including all-cause mortality, stroke, major vascular complications, life-threatening bleeding, and new dialysis were similar between CATH and OR (p = all ns). There was no difference in conversion to open heart surgery between CATH and OR with both occurring at a very low rate (0.4% vs. 0.5%, p = 0.07). Moreover, the 30-day survival post-conversion was similar whether TAVR was performed in CATH versus OR (43.3% and 49.7%, p = 0.28). When stratified by STS Risk Score, there was no difference in conversion to surgery or 30-day mortality in low and intermediate risk patients between CATH and OR. For high risk patients, however, conversion to surgery was lower in CATH vs. OR (0.2% vs. 0.4%, p = 0.04) with no difference in 30-day survival (46% vs. 43%, p = 0.94).

    Conclusions

    Procedure location has minimal impact on TAVR procedural and 30-day outcomes with a very low conversion to open surgery rate between CATH versus OR for low, intermediate, and high-risk patients.