The absolute margin was kept even though events were rarer than anticipated, which made it less conservative on a relative scale than intended, the investigators cautioned. The results were presented Monday in a late-breaking session at Transcatheter Cardiovascular Therapeutics (TCT) 2026 in San Diego, California, by trial investigator Dr Nicolas Majunke, from the Heart Center Leipzig at Leipzig University, Germany. The investigator-initiated trial — sponsored by Leipzig Heart Science, with an institutional grant and in-kind software support from Pie Medical Imaging — was simultaneously published in JACC by Majunke and colleagues. “As we all know, wire-based FFR is guideline recommended, but remains underused in clinical practice,” Dr Majunke said. Angiography-derived FFR removes the need for a pressure wire and may make physiology-guided revascularization easier, he added. Yet, the 3 randomized trials comparing angiography-derived FFR with wire-based FFR have given mixed results. FAVOR III Europe, which used quantitative flow ratio (QFR), did not demonstrate noninferiority, whereas ALL-RISE, using FFRangio, and FAST III, using vFFR, did. “These heterogeneous findings suggest that results obtained with one angiography-derived physiological method cannot necessarily be extrapolated to another and that each platform requires separate evaluation,” Majunke and colleagues wrote. The current study therefore set out to provide a second, separately conducted randomized evaluation of the vFFR platform tested in FAST III. Between June 2020 and February 2025, 1,053 patients with intermediate stenoses of 40% to 90% and chronic coronary syndrome (CCS), or acute coronary syndrome (ACS) with non-culprit lesions, were randomized at 8 German centers to vFFR-guided (n = 528) or FFR-guided (n = 525) revascularization. In both arms, values of 0.80 or below prompted percutaneous coronary intervention (PCI), and PCI was deferred for higher values. Median age was 68 years in the vFFR group vs 70 years in the FFR group, and most patients had CCS (86.3% vs 88.8%). Margin kept after reassessment The original design assumed a 1-year MACE rate of 8.0% and an absolute noninferiority margin of 3.5%, requiring 1,926 patients. Following slower-than-expected enrollment, a blinded sample-size reassessment in March 2024 found a pooled 1-year MACE rate of 4.2%, cutting the target to 1,054 patients. “What is important is that the absolute non-inferiority margin remained unchanged despite the lower event rate,” Dr Majunke stressed. The primary outcome — a composite of cardiac death, non-fatal myocardial infarction or unplanned clinically driven revascularization — was ascertainable in 986 of the 1,053 randomized patients. At 1 year, MACE occurred in 3.0% of the vFFR group and 4.1% of the FFR group (15 of the 493 vs 20 of 493); absolute difference: -1.0%; 95% confidence interval [CI]: -3.3 to 1.3; P for noninferiority < 0.001). The upper boundary of the 1-sided 97.5% CI, at 1.29%, was below the 3.5% margin. The corresponding relative risk was 0.75 (95% CI: 0.39-1.45), the researchers reported. In a post hoc sensitivity analysis applying the relative margin of 1.44 implied by the original design assumptions, noninferiority was not met in the primary analysis, with an upper relative-risk boundary of 1.45, but was met in the per-protocol population, at 1.37. The authors stressed that these were sensitivity analyses around the prespecified decision rule, not alternative primary analyses. The individual components of MACE occurred at similar rates, with cardiac death in 1.2% vs 2.1%, myocardial infarction in 1.2% vs 1.4% and unplanned clinically driven revascularization in 1.0% vs 0.8%. Other secondary and safety outcomes, which were exploratory, were also similar between groups, and exploratory subgroup analyses showed no relevant interactions, though event rates were low, Dr Majunke said. More lesions treated, consequence ‘uncertain’ Median measurement time was 5 minutes with vFFR vs 12 minutes with FFR. A physiological value of 0.80 or below was found in 43.1% vs 35.9% of patients, and the study lesion was revascularized in 41.2% vs 35.5%, a difference of 5.7% (95% CI: −0.2 to 11.6), the researchers reported. The same pattern was seen in FAST III, Dr Majunke noted. “Finally, vFFR identified more physiologically significant lesions and led to more revascularization with uncertain clinical consequences,” he said. The extra procedures may reflect ischemia-producing lesions that would otherwise go untreated, or a downward shift in measured values leading to treatment of lesions unlikely to benefit, the authors noted. “The present finding of similar clinical outcomes at 1 year does not distinguish between these possibilities and should not be read as evidence that each additional procedure was beneficial,” they wrote. The findings apply mainly to patients with CCS, since only 12.5% presented with ACS, the researchers added, and come from 8 experienced centers in an open-label design that excluded complex lesions. Resolving the question would require outcome data at the vessel level for lesions that the 2 methods classify differently, and therefore paired measurements in the same patient, they noted. Long-term follow-up of up to 5 years is ongoing. Source:Majunke N, Desch S, Kister T, et al. Angiography-Derived versus Wire-Based Fractional Flow Reserve to Guide Revascularization: The Randomized LIPSIA-STRATEGY Trial. J Am Coll Cardiol 2026; DOI: 10.1016/j.jacc.2026.10.064. Image Caption: Bernardo Cortese, MD, presents during a press conference Monday, November 2, at the Transcatheter Cardiovascular Therapeutics (TCT) 2026 conference in San Diego. Image Credit: Screenshot by Nathan Gray, CRTonline.org.